A roof fall was discovered 3 main 16-314 xcut #8 hdg. Fall above anchorage 18' x 18' x 6' high. Area was bolted with 6' fully grouted resin bolts and 12' passive cable bolts. No men or machines were trapped or injured. No ventilation or travel was affected.