A roof fall was discovered on this date. The fall was located on 1-left 2 belt between the #60 and #61 breaks in the #3 entry. The fall measured 20' x 70' and was 8' in thickness. The area was previously supported with 5' hy-tech bolts and 8' superbolts. The fall area will be cleaned up and re-supported. The fall was immediately reported to MSHA.