# FALL OF ROOF OR BACK
> MSHA accident `220082530026` · 08/29/2008 · American Energy Corporation
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Robert E  Murray
- **Operator:** American Energy Corporation
- **Mine:** [3301070](https://api.ai-analytics.org/mine/3301070)
## Narrative

A roof fall was found on the South Mains ""D"" mainline belt at 28 x-cut. Fall was approx. 30' long by 26' wide by 7 to 8' high. Fall did not obstruct ventilation or escapeways. Area bolted with 8' Install III bolts with resin assisted with supplemental support consisting of bacon straps, wood cribs and 4"" H-beams. Cause of this fall was weathering of the roof.

---