FALL OF ROOF OR BACK

220082600032 · 09/10/2008 · Consolidation Coal Company

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
0
Mine experience
— years

Operator

Controller (parent)
CONSOL Energy Inc
Operator
Consolidation Coal Company
Mine
4404856

Narrative

An unintentional roof fall was dicovered on Grassy Creek Mains at crosscut #18 in the #8 entry. Survey station #10354. The fall measured approx 20' X 20' X 8' high. The fall has been dangered off and additional supports implemented on all sides. No one was injured, ventilation was not interrupted and no equipment was caught. This fall will not be cleaned up.