A roof fall was discovered north B 13 x # 3 Hdg intersection. Fall above anchorage. 18' x 18' x 7' high. 6' fully grouted resin bolts were in use. No equipment or persons were injured or trapped. No ventilation or travel was impeeded. This fall was approx 3,000' outby the working section.