A roof fall was discovered at 16x 3 main #7 Hdg intersection only. 18' x 18' x 12' high. Fell above anchorage of 6' fully grouted resin bolts aand 8 @ 12' cable bolts. No men or equipment were injured or trapped. No ventilation or travel was affected. This fall was approx 4,500 feet outby the section.