On 3-n sect. #4 inter, 4 BL. 100' inby spad 5138 Fell in approx. 15-20' high 16'w x 20'L top was gray shale laminated. Water was evident in top after fall. Cover of 270' area bolted with 6' resin bolts and 12' cable bolts. x3-4 was cribbed off also. Fall will be cleaned up and heizman canopy installed called MSHA hot line.