A roof fall was discovered at 3 main 53x#8 hdg intersection 18x 18x24. Fell above the anchorage of 6' super twist bolts and 4 @ 12' post tesnion cable bolts. approx 2,400' outby the face. no men or equipment were injured or trapped no ventilation or travel was impeeded.