← MSHA accidents

IGNITION OR EXPLOSION OF GAS OR DUST

220083230032 · 11/14/2008 · Canyon Fuel Company LLC

Details

Degree of injury
ACCIDENT ONLY
Classification
IGNITION OR EXPLOSION OF GAS OR DUST
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
0
Mine experience
— years

Operator

Controller (parent)
Arch Resources Inc
Operator
Canyon Fuel Company LLC
Mine
4201890

Narrative

A frictional methane ignition occured in the 9th East CM section. Operator was turning a crosscut (15' depth) when the miner bits contacted fallen roof rock. The miner head was 1' above the floor when the ignition occurred. It appears that a spark was generated from the sandstone, subsequently igniting a methane floor feeder. The ignition lasted less than 10 seconds.

Source

Authoritative
MSHA Open Government Data
Machine
JSON-LD · Markdown