← MSHA accidents

IGNITION OR EXPLOSION OF GAS OR DUST

220083230032 · 11/14/2008 · Canyon Fuel Company LLC

Details

Degree of injury
ACCIDENT ONLY
Classification
IGNITION OR EXPLOSION OF GAS OR DUST
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
0
Mine experience
— years

Operator

Controller (parent)
Arch Resources Inc
Operator
Canyon Fuel Company LLC
Mine
4201890

Narrative

A frictional methane ignition occured in the 9th East CM section. Operator was turning a crosscut (15' depth) when the miner bits contacted fallen roof rock. The miner head was 1' above the floor when the ignition occurred. It appears that a spark was generated from the sandstone, subsequently igniting a methane floor feeder. The ignition lasted less than 10 seconds.

Source

Authoritative
MSHA Open Government Data