A frictional methane ignition occured in the 9th East CM section. Operator was turning a crosscut (15' depth) when the miner bits contacted fallen roof rock. The miner head was 1' above the floor when the ignition occurred. It appears that a spark was generated from the sandstone, subsequently igniting a methane floor feeder. The ignition lasted less than 10 seconds.