A roof fall was found on 12/2/08 at 10:35 at x-cut 47 entry 5 of the main west. Fall was 20' x 20' x 10' high in a 4-way intersection. Area was mined September 2001 and had been supported with 8' resin pins. No property damage or injury resulted. At this time there are no plans to clean this fall up.