← MSHA accidents

HOISTING

220083500021 · 12/05/2008 · Chevron Mining Inc

Details

Degree of injury
ACCIDENT ONLY
Classification
HOISTING
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
0
Mine experience
— years

Operator

Controller (parent)
Chevron Corporation
Operator
Chevron Mining Inc
Mine
0100759

Narrative

The hoist rope for the Flat Creek Main Emergency Escape Capsule broke during a functionality test. Ice had accumulated on the guide ropes which stopped the capsule's descent, allowed slack to gather in the rope, and allowed the capsule to drop the corresponding distance of the slack in the rope, which resulted in breakage of the hoist rope.

Source

Authoritative
MSHA Open Government Data
Machine
JSON-LD · Markdown