← MSHA accidents

FALL OF ROOF OR BACK

220083570042 · 12/18/2008 · ICG Hazard LLC

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
0
Mine experience
— years

Operator

Controller (parent)
International Coal Group Inc (ICG)
Operator
ICG Hazard LLC
Mine
1518850

Narrative

The above mentioned mine has experienced a non-injury, unintentional roof fall on the #5 conveyor belt at x-cut #10. The fall strata was shale, app. 30 feet in width, app. 23 feet in width and 4 feet thick. 48 Inch fully grouted rods and 10 foot cable bolts was the initial support.

Source

Authoritative
MSHA Open Government Data
Machine