A roof fall occurred in the track entry on the one south track area at x-cut #10. The area was bolted with 5 ft bolts and cribs on the side. The fall will be cleaned up and the area will be rebolted and cribed. The fall was about 20 ft long, 19 ft wide and 5 to 8 foot high.