A roof fall was found in 9 mains-#5 Butt-#3 Entry approx 40' inby station #5190. The fall was approx 6' high, 19' wide and 40' long. The area was bolted with 6' fully grouted torque tensioned bolts. The area is dangered off. The fall does not impede ventilation or travel.