# FALL OF ROOF OR BACK
> MSHA accident `220090020041` · 12/21/2008 · Consol of Kentucky Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** CONSOL Energy Inc
- **Operator:** Consol of Kentucky Inc
- **Mine:** [1518589](https://api.ai-analytics.org/mine/1518589)
## Narrative

An unintentional roof fall occurred in the #4 entry at spad #9491. The fall was estimated to be 4 ft high by 18 ft wide by 60 ft long. This area was bolted with 4 ft resin bolts with 10 ft cable bolts in the intersection. No injuries, track & belt was caught, ventilation was not interupted. The fall will be cleaned up.

---