The mine encountered a roof fall at 19+25, entry #5, of the Main Northwest. The fall measured 4'L X 18'W X 4' thick. The event was called in at 7:30PM. 103(k) issued at 7:55AM on 1/5/2009. The area was developed 7/10/2002, bolted with 12' point anchor and truss bolts. The fall will be cleaned up.