A roof fall was found at 11:30 PM on 1/11/2009 between x-cut 45 and 46 entry #2 main south. Fall was approximately 20 x 20 x 7' high. Area had been mined May of 1990 and was supported with 8' full resin bolts. The fall will be cleaned up and supported following clean up plan approved by MSHA district manager.