← MSHA accidents

FALL OF ROOF OR BACK

220090140014 · 01/13/2009 · Peabody Midwest Mining, LLC

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
0
Mine experience
— years

Operator

Controller (parent)
Peabody Energy Corporation
Operator
Peabody Midwest Mining, LLC
Mine
1102408

Narrative

An unintentional roof fall occurred on Unit #2 at Entry #7 at 55+90. the fall occurred due to a slip running through the intersection. The fall area was originally supported with 5 foot conventional roof bolts. The fall is aproximately 15 feet long, 25-30 feet wide, 5-6 feet high. The fall will be cleaned up and resuppported with 6 foot double lock roof bolts.

Source

Authoritative
MSHA Open Government Data
Machine