An unplanned roof fall was discovered in the #1 entry, approx 3000' outby the #1 working section. All enterances were dangered off and this area will not be rehabilitated. This area was bolted with 6' torque tension bolts and 12' cable bolts. The fall measured 60' long X 18' wide X 7' thick.