A roof fall measuring, 80' L, 19' W, and 8' thick was found in the crosscut between 3&4 entries on 4 belt spad 58667. The area developed Oct 07 was 5500' from the working place, it affected no persons. It occurred due to coal and rock streaks above the 5' torque tension roof bolts.