An unplanned roof fall was discovered on a weekly exam on 1/22/09 measuring 60' in length, 19' in width & 8' in height at spad #3031 approx. 3500' from the working face. Entrances have been dangered & breakered off & the area will not be rehabilitated. This was an old return on a panel. MSHA was notified on 1-22-09 & Judy at the Danville state office notified 1-22-09.