A roof fall was discovered by the fireboss and MSHA inspector while making the return entries. The fall measured 120 ft in length x 19 ft in width x 10 ft high. It is appx. 7,900 ft from the section in the #1 entry at spad # 3108. The fall has been breakered off and will be rehabilitated. The area was bolted with 6 ft torque tension bolts. No rider seam is present.