# HOISTING
> MSHA accident `220090720002` · 03/11/2009 · Morton Salt Div/Morton International Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** HOISTING
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Rohm & Haas Company
- **Operator:** Morton Salt Div/Morton International Inc
- **Mine:** [3301993](https://api.ai-analytics.org/mine/3301993)
## Narrative

An unknown electrical problem rendered the Production hoist inoperable.  There were no persons underground at the time.  Trouble-shooting revealed a contactor linkage had gone out of adjustment; back in operation at 12:45pm.

---