An unintentional roof fall occured at #71 cross cut on the Main North Entry #3. The fall did not affect ventilation, passage of men or cause personal injury. The fall measured 20 feet x 20 feet x 6 feet. The area had been roof bolted with 6 ft. fully grouted roof bolts.