# FALL OF ROOF OR BACK
> MSHA accident `220090890074` · 03/22/2009 · Mingo Logan Coal LLC
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Arch Resources Inc
- **Operator:** Mingo Logan Coal LLC
- **Mine:** [4609029](https://api.ai-analytics.org/mine/4609029)
## Narrative

Unintentional fall of mine roof located in the Intake entry at 97 X-cut, in the North Main on the right side. The fall is approx 45' long, 20' wide and 10' high. Distance from the active face is 4,000 feet. Ventilation to the section is uninterrupted. All the EE's have been instructed to use #2 primary escapeway. The Foreman and crews have traveled this escapeway.

---