A foof fall was found at 10PM at x-cut 253xc entry 4, main south. The fall was in a 4-way intersection that had been mined in September 1997 & was supported with 4 & 8 foot full resin bolts. Additional props had been added recently to reduce entry width. No injuries resulted, some cable and waterline were lost. There are no immediate plans to clean this fall up.