A roof fall occurred in the belt entry of the 5th Panel North. The fall covered the 2A belt tail piece. No injuries or disruptions to ventilation. The fall was approx. 50' long by 6' high by 19.5' wide. The fall was discovered by a repairman at about 5:30PM. Fall was a Spad 5+04 (XC 12) in No. 6 entry of 5th panel north off 1st main east.