An unintentional roof fall occurred on Unit #3 at Entry #7 at 18+60. The fall occurred due to a slip running through the intersection. The fall was originally supported with 5 and 6 ft. conventional bolts. The fall is approximately 30 ft. long, 20 ft. wide and 5-7 ft. high. The fall will be cleaned up and resupported.