An unintentional roof fall occurred on the 4C return at 9+80 station in the #2 entry. The roof fall measured 24 foot x 25 foot x 6 foot. The fall did not affect ventilation, passage of men or cause personal injury. The fall occurred in a 4-way intersection. The fall had been bolted with 6 foot roof bolts.