# FALL OF ROOF OR BACK
> MSHA accident `220091870071` · 06/30/2009 · Pine Ridge Coal Company LLC
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Patriot Coal Corporation
- **Operator:** Pine Ridge Coal Company LLC
- **Mine:** [4607908](https://api.ai-analytics.org/mine/4607908)
## Narrative

Unintentional roof fall: d-intake, No 8 entry, intersection at No. 15, crosscut, 80 ft inby survey station No. 10013. The fall measured approx. 20ft long, 20 ft wide and 6 ft thick. Five foot fully grouted resin roof bolts were in use as primary roof support.

---