← MSHA accidents

FALL OF ROOF OR BACK

220092230043 · 08/08/2009 · Consolidation Coal Company

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
0
Mine experience
— years

Operator

Controller (parent)
CONSOL Energy Inc
Operator
Consolidation Coal Company
Mine
4601436

Narrative

On August 8, 2009 an unintentional roof fall occurred at the 48+50 plus marker of the main east entries track entry. The roof fall measured approximately 50' long x 14' high & 17' wide. The fall did not cause any injuries, no entrapments and ventilation was not disturbed. The area had been supported with conventional roof bolts, crossbeams with lagging and 12' cable bolts.