A roof fall occurred on the 2-East Return in the #1 Entry between the #27 and #29 crosscuts. The fall started inby X-cut #27 and ended outby x-cut #29. The fall was around 8' in thickness. The area was previously supported with 5' Hy-Tech Bolts supplemented with 8' cable bolts.