The roof fall occured at the 1st of left hand rooms number 6 belt, 3 crosscuts to the left of spad 4244. The length of the fall was 60""long, 18' wide, 5 1/2"" high. The passage of the men were not eggected. No injuries occured from this fall. The fall will not be cleaned up. The time of the roof fall was 10:20 pm Person reported the fall at 10:50 pm ...fall have been supported