During a preshift examination by a fireboss he found a roof fall in the 1st North section at #3 entry x-cut #9. The roof fall was approximately 15' x 15' x 6' high and the area had been bolted with 6' resin bolts. The fall was not in an escapeway and did not impede ventilation. Travel was rerouted around the cave area.