← MSHA accidents

FALL OF ROOF OR BACK

220092430029 · 08/19/2009 · Consolidation Coal Company

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
0
Mine experience
— years

Operator

Controller (parent)
CONSOL Energy Inc
Operator
Consolidation Coal Company
Mine
4200079

Narrative

During a preshift examination by a fireboss he found a roof fall in the 1st North section at #3 entry x-cut #9. The roof fall was approximately 15' x 15' x 6' high and the area had been bolted with 6' resin bolts. The fall was not in an escapeway and did not impede ventilation. Travel was rerouted around the cave area.

Source

Authoritative
MSHA Open Government Data
Machine
JSON-LD · Markdown