FALL OF ROOF OR BACK

220092880013 · 10/10/2009 · American Energy Corporation

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
0
Mine experience
— years

Operator

Controller (parent)
Robert E Murray
Operator
American Energy Corporation
Mine
3301070

Narrative

A roof fall was found on South B beltline inby xcut #23. Fall was approx. 35 feet long by 15 feet wide by 2 to 12 feet high. Area was bolted with Install II bolts and resin assisted. The supplemental support consisted of bacon straps, wire mesh screen, cribs and ""I"" beams. Fall was caused by deterioration of the mine roof through weathering.