A roof fall was found on South B beltline inby xcut #23. Fall was approx. 35 feet long by 15 feet wide by 2 to 12 feet high. Area was bolted with Install II bolts and resin assisted. The supplemental support consisted of bacon straps, wire mesh screen, cribs and ""I"" beams. Fall was caused by deterioration of the mine roof through weathering.