← MSHA accidents

FALL OF ROOF OR BACK

220093030010 · 10/28/2009 · Rio Group, Inc.

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
0
Mine experience
— years

Operator

Controller (parent)
Richard H Abraham
Operator
Rio Group, Inc.
Mine
4608570

Narrative

Discovered a roof fall in the HL1 panel that fell from spad #3098 thru the break to spad #3102. Fall is 4-5' thick x 20' wide x 70' long in both intersections and the break. This area was bolted with #5 x 48"" fully-grouted resin roof bolts. This area is 2700' from the section and has been dangered off.

Source

Authoritative
MSHA Open Government Data
Machine
JSON-LD · Markdown