A roof fall was found by pre-shift examiner in a four way instersection adjacent to # 12 & 13 1 west seals at 11:45am on 10/30/2009. Area had been supported with 6' full resin pins and had been truss bolted. No injury resulted. No plans to clean up the fall. Pending approval of a seal plan from MSHA, new seals will be built to replace those which are inaccessable.