An unintentional roof fall was discovered on 11/3/2009 by mine examiners conducting their weekly exam of an abandoned area of the mine. The fall was located in XC #5, between entries 4 and 5 of the 1 Left/5 main North. The fall measured 18' L X 18' W X 8' Thick and was bolted with 6' resin bolts. The area was developed in 5/07.