A roof fall was found by the asst mine manager at 3:18am and reported to MSHA at 3:30am. Fall is located at X-cut 43, Entry #3 of the M-3 zone. It is 20' side, 25'long, and fell 12' high. The area was supported with 6' fully grouted roof bolts and was developed on 8/15/09. This fall did not affect ventilation, passage of miners or cause personal injury to any miner.