Pre-shift examiner was preshifting mine for Tues AM in 4 West Section. He stopped at pump along Intake in #7 Entry, he smelled fresh resin. He went ouby 5 xcut in #7 Entry where he found a roof fall in the Inter. 4 xcut outby STA at 8152. This had been bolted with 4.5 2 piece bolts & 8' cable bolts. Area is cribbed off & abandoned. Fall measured approx 35' long 70""x 8"" high in Int.