# HOISTING
> MSHA accident `220093490007` · 12/04/2009 · Independent Salt Company
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** HOISTING
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** M D  Keener
- **Operator:** Independent Salt Company
- **Mine:** [1400411](https://api.ai-analytics.org/mine/1400411)
## Narrative

The main hoist would not start.  After checking system over, the operating parameters were changed allowing the M.G. Set to start.  However, the voltage level was twice the norm.  The Static Field Comp, which was believed to have failed, was replaced.  The operating parameters were returned to original settings, the hoist operated and was placed back in service.

---