# FALL OF ROOF OR BACK
> MSHA accident `220093500003` · 12/08/2009 · American Energy Corporation
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Robert E  Murray
- **Operator:** American Energy Corporation
- **Mine:** [3301070](https://api.ai-analytics.org/mine/3301070)
## Narrative

A roof fall was found on the 22 East track entry at 49 cross cut. The fall was approx. 30 feet long by 17 feet wide and 2 to 10 feet high. Area was bolted with Install III bolts with resin assisted. The area was screened and we used bacon straps. Fall fell above anchorage point.

---
*Source: [MSHA Open Government Data](https://arlweb.msha.gov/OpenGovernmentData/) · AI Analytics · CC0 1.0*