# FALL OF ROOF OR BACK
> MSHA accident `220093520025` · 12/17/2009 · Consol of Kentucky Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** CONSOL Energy Inc
- **Operator:** Consol of Kentucky Inc
- **Mine:** [1518589](https://api.ai-analytics.org/mine/1518589)
## Narrative

An unintentional roof fall was discovered on the 004 section in the #4 entry between #3 and #5 break. Size of fall was estimated to be 120' L X 7-8' H X 18-20' W. The area had been supported with 6' fully grouted resin bolts. No injuries, no equipment caught or ventilation was disrupted. Fall will not be cleaned up.

---