# FALL OF ROOF OR BACK
> MSHA accident `220093560014` · 12/18/2009 · Big Ridge Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Peabody Energy Corporation
- **Operator:** Big Ridge Inc
- **Mine:** [1103054](https://api.ai-analytics.org/mine/1103054)
## Narrative

An unintentional roof occurred on the 4C panel,  station 32+90 entry #4 in the neutral on the backside of the belt.  Ventilation was not affected.  It did not cause personal injury or affect the passage of men.   The fall measured 18foot x 18foot x 6 foot high.  The area had been bolted with 4 and 6 foot fully grouted roof bolts.

---
*Source: [MSHA Open Government Data](https://arlweb.msha.gov/OpenGovernmentData/) · AI Analytics · CC0 1.0*