The area where the fall occurred is a bleeder travelway for the 3 North Panel. One fall occurred in the intersection at 29 Break along the #1 Entry. The area was bolted on advance with 6' fully grouted resin bolts. Some areas around the fall were cribbed previously. Fall varies from 6 to 7 feet in height, and 17 feet wide by 18 feet long. Approximately 500' of cover.