A roof fall was discovered on this date. The fall was located on MMU-005 in the #3 entry at break #49. The fall measured 20' by 20' and was 8' in thickness. The area was previously supported with 5' Hy-Tech Bolts and 12' Superbolts. The fall occurred during an idle shift, with no personnel present.