A roof fall occurred on this date. The fall was located on 002 section in the 7-Left Panel off C-Mains in the #1 entry at break #13. The fall measured 25' by 18' and was 8' in thickness. No miners or equipment were affected. This section has been moved to another location in the mine. The area was previously supported with 5' Hy-Tech bolts and 12' cable bolts.