Approx. 6:30a.m. on 2/16/10 a continuation of an existing roof fall was found in the #9 entry at spad 10400 approx.600' outby the working section. The fall was approx.20'W X 40'L X 6'H. The area was supported with 5' fully grouted resin bolts. The area will not be cleaned up. The area has been dangered off and timbers set.