While mining in the inby 3x4 crosscut everyone heard and felt a roof fall. Upon investigating it the Foreman found a fall in #4 Entry of the section adjacent to the fail in #4 Entry. This fall was 20' wide and 55' long. It came above the 4' resin bolts and also took cable bolts out in the intersection. Roof was very thinly laminated and broke up.