# HOISTING
> MSHA accident `220100910035` · 03/24/2010 · Morton Salt Div/Morton International Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** HOISTING
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** K+S Aktiengesellschaft
- **Operator:** Morton Salt Div/Morton International Inc
- **Mine:** [4101776](https://api.ai-analytics.org/mine/4101776)
## Narrative

The #1 hoist speed control contactor stuck on control #3. An electrician was called to replace the entire switch with a new one. The miners were evacuated at 9:38am the evacuation was completer at 9:58am. The contactor relay switch was replaced and the hoist was tested. Miners returned u/g at 10:40am.

---